Products Recorders
TESLA 3000 Multi-timeframe Power System Disturbance Fault Recorder (DFR) with advanced Phasor Measurement Unit (PMU) and Continuous Disturbance Recording (CDR) capabilities
TESLA is a multi-timeframe power system disturbance fault recorder that simultaneously provides fault oscillography, dynamic swing recording and event logging. TESLA 3000 adds the ability to combine multiple recorders into a larger virtual unit via Ethernet communications.
- 36 analog/64 external input channels, 1000 record storage capacity. Up to four recorders can be operated as a cooperative group to achieve greater numbers of channels
- Up to 150 virtual channels, provides cost efficiency & flexibility.
- Transient Faults – User selectable 32, 64, 96,128,256 and 384 samples/cycle oscillography, up to 10 second records.
- Dynamic Swings - 1 sample/cycle, up to 30 minute records.
- Trend - 90 day user-defined trend log.
- Easy to use, simplified recorder setting & record analysis software (Windows 9x/ME/NT/2000) included.
The TESLA 3000 multi-timeframe power system disturbance fault recorder (DFR) provides the following features:
- Independent triggering for fault or dynamic swing recording with priority record functionality.
- Trigger on rates & levels for quantities measured, summation, sequence components, watts, vars, frequency, impedance, harmonic & THD channels.
- No mechanical moving parts - Non-volatile on board flash memory eliminates most common mode of failure in recorders. Each flash drive holds 1000 records
- ProLogic - control logic statements.
- Three communication RS-232 ports. Internal modem option.
- Direct-connect DNP3 & Modbus SCADA communication protocols (Ethernet ready).
- IRIG-B time stamping & sample synchronization.
PMU Module
The PMU module adds synchronized phasor measurement functionality to TESLA Model 3000 Disturbance Fault Recorders.
- IEEE C37.118-2005 standard for synchrophasors for power systems
- Add-on module provides PMU functionality to a new or existing installation
- Fault recorder functionality and PMU technology integrated in a single box
CDR (Continuous Disturbance Recording) Module
- Compliant with PRC-002-1 NERC standard for continuous disturbance recording and reporting
- TESLA exceeds the NERC requirements of at least 960 samples/second and RMS values recorded at a rate of at least 6 records/second
- TESLA exceeds the NERC requirements of 10 days storage of disturbance data sampled at above rates
|
|
|